Detail Specifications
Overall Height:
2.125 inches
Body Length:
3.500 inches
Body Height:
1.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.000 inches
Vibration Resistance Range In Hertz:
+10.0/+55.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.250 inches
Operating Tempurature Range:
+0.0/+65.0 degrees celsius
Reference Frequency Per Function:
30.7465 hercules no.5599.1 pulses per second
Reference Frequency Per Function:
30.7465 hercules no.5599.1 two phase to three phase
Reference Frequency Per Function:
30.7465 hercules no.5599.1 two phase to two phase
Input Impedance Per Function W/load:
50.0 ohms 3rd band pass
Input Impedance Per Function W/load:
50.0 ohms 1st band pass
Input Impedance Per Function W/load:
50.0 ohms 2nd band pass
Output Impedance Per Function W/source Across Input:
50.0 ohms 2nd band pass
Output Impedance Per Function W/source Across Input:
50.0 ohms 3rd band pass
Output Impedance Per Function W/source Across Input:
50.0 ohms 1st band pass
Principal Circuitry Type Per Function:
Inductance-capacitance blank
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
4 threaded stud
Insertion Loss At Reference Frequency Per Function In Decibels:
2.5 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
2.5 2nd band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
2.5 3rd band pass
Functional Terminal Type And Quantity:
3 connector, receptacle input 1st function
Functional Terminal Type And Quantity:
6 connector, receptacle output 2nd function
Specified Frequencies Of Discrimination Per Function:
10.00 megahertz 1st band pass 1st function and 30.50 megahertz 1st band pass 1st function and 30.94 megahertz 1st band pass 1st function and 80.00 megahertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function:
10.00 megahertz 3rd band pass 3rd function and 30.50 megahertz 3rd band pass 3rd function and 30.94 megahertz 3rd band pass 3rd function and 80.00 megahertz 3rd band pass 3rd function
Specified Frequencies Of Discrimination Per Function:
10.00 megahertz 2nd band pass 2nd function and 30.50 megahertz 2nd band pass 2nd function and 30.94 megahertz 2nd band pass 2nd function and 80.00 megahertz 2nd band pass 2nd function
Thread Size:
0.112 inches
Frequency Band Width Per Function:
30.50 megahertz 1st band pass and 30.94 megahertz 1st band pass
Frequency Band Width Per Function:
30.50 megahertz 2nd band pass and 30.94 megahertz 2nd band pass
Frequency Band Width Per Function:
30.50 megahertz 3rd band pass and 30.94 megahertz 3rd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 60.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 3.0 3rd band pass 3rd function and 60.0 3rd band pass 3rd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 1st band pass 1st function and 3.0 1st band pass 1st function and 3.0 1st band pass 1st function and 60.0 1st band pass 1st function
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Tunable Bandreject Filter
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC